433![NC Department of Environment and Natural Resources T15A: 18A[removed]This contains amendments effective February 1, 2004 TITLE 15A – DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES NC Department of Environment and Natural Resources T15A: 18A[removed]This contains amendments effective February 1, 2004 TITLE 15A – DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES](https://www.pdfsearch.io/img/f5ba91f76e7f5e40c40370f5918df178.jpg) | Add to Reading ListSource URL: ehs.ncpublichealth.comLanguage: English - Date: 2012-02-21 11:03:01
|
---|
434![15A NCAC 18A[removed]MINIMUM STANDARDS FOR PRECAST REINFORCED CONCRETE TANKS (a) The following are minimum standards of design and construction of precast reinforced concrete septic tanks: (1) The minimum requirement for t 15A NCAC 18A[removed]MINIMUM STANDARDS FOR PRECAST REINFORCED CONCRETE TANKS (a) The following are minimum standards of design and construction of precast reinforced concrete septic tanks: (1) The minimum requirement for t](https://www.pdfsearch.io/img/b92230d19588365a38c108d24dad2fad.jpg) | Add to Reading ListSource URL: reports.oah.state.nc.usLanguage: English - Date: 2013-04-12 06:09:52
|
---|
435![15A NCAC 18A[removed]APPROVAL AND PERMITTING OF ON-SITE SUBSURFACE WASTEWATER SYSTEMS, TECHNOLOGIES, COMPONENTS, OR DEVICES (a) Experimental, controlled demonstration, and innovative wastewater systems (hereinafter referr 15A NCAC 18A[removed]APPROVAL AND PERMITTING OF ON-SITE SUBSURFACE WASTEWATER SYSTEMS, TECHNOLOGIES, COMPONENTS, OR DEVICES (a) Experimental, controlled demonstration, and innovative wastewater systems (hereinafter referr](https://www.pdfsearch.io/img/41e0dde218db726a75b62750b130e05c.jpg) | Add to Reading ListSource URL: reports.oah.state.nc.usLanguage: English - Date: 2013-04-12 06:27:40
|
---|
436![15A NCAC 18A[removed]RESPONSIBILITIES (a) The permitting of a wastewater system shall be the responsibility of agents authorized by the State in accordance with G.S. 130A-40, 130A-50, and registered with the State of North 15A NCAC 18A[removed]RESPONSIBILITIES (a) The permitting of a wastewater system shall be the responsibility of agents authorized by the State in accordance with G.S. 130A-40, 130A-50, and registered with the State of North](https://www.pdfsearch.io/img/dba1b793e109d1214c19d22aff3e3074.jpg) | Add to Reading ListSource URL: reports.oah.state.nc.usLanguage: English - Date: 2013-04-12 05:49:57
|
---|
437![15A NCAC 18A[removed]SEWAGE FLOW RATES FOR DESIGN UNITS (a) In determining the volume of sewage from dwelling units, the flow rate shall be 120 gallons per day per bedroom. The minimum volume of sewage from each dwelling u 15A NCAC 18A[removed]SEWAGE FLOW RATES FOR DESIGN UNITS (a) In determining the volume of sewage from dwelling units, the flow rate shall be 120 gallons per day per bedroom. The minimum volume of sewage from each dwelling u](https://www.pdfsearch.io/img/b86fffa2faf613b658268282ce6b3beb.jpg) | Add to Reading ListSource URL: reports.oah.state.nc.usLanguage: English - Date: 2013-04-12 06:03:40
|
---|
438![15A NCAC 18A[removed]DEFINITIONS The following definitions shall apply throughout this Section: (1) 15A NCAC 18A[removed]DEFINITIONS The following definitions shall apply throughout this Section: (1)](https://www.pdfsearch.io/img/fb20ca5d4c40bdfad8d771d342cea684.jpg) | Add to Reading ListSource URL: reports.oah.state.nc.usLanguage: English - Date: 2013-04-12 05:45:45
|
---|
439![Microsoft Word - 15a ncac 18a[removed]doc Microsoft Word - 15a ncac 18a[removed]doc](https://www.pdfsearch.io/img/e9b97483e28cd3c1e74d1ea5b9dfeabc.jpg) | Add to Reading ListSource URL: ehs.ncpublichealth.comLanguage: English - Date: 2012-02-21 11:03:01
|
---|
440![15A NCAC 18A[removed]CRITERIA FOR DESIGN OF ALTERNATIVE SEWAGE SYSTEMS (a) LOW-PRESSURE PIPE SYSTEMS: Low-pressure pipe (LPP) systems with a two to five-foot pressure head may be utilized on sites which are SUITABLE or PRO 15A NCAC 18A[removed]CRITERIA FOR DESIGN OF ALTERNATIVE SEWAGE SYSTEMS (a) LOW-PRESSURE PIPE SYSTEMS: Low-pressure pipe (LPP) systems with a two to five-foot pressure head may be utilized on sites which are SUITABLE or PRO](https://www.pdfsearch.io/img/422d3282bd0f86db6867e9400975640b.jpg) | Add to Reading ListSource URL: reports.oah.state.nc.usLanguage: English - Date: 2013-04-12 06:13:20
|
---|