18A

Results: 550



#Item
431Microsoft Word - 15a ncac 18a[removed]doc

Microsoft Word - 15a ncac 18a[removed]doc

Add to Reading List

Source URL: ehs.ncpublichealth.com

Language: English - Date: 2012-08-08 16:30:46
432Microsoft Word - 15a ncac 18a[removed]doc

Microsoft Word - 15a ncac 18a[removed]doc

Add to Reading List

Source URL: ehs.ncpublichealth.com

Language: English - Date: 2012-08-08 16:40:28
433NC Department of Environment and Natural Resources  T15A: 18A[removed]This contains amendments effective February 1, 2004 TITLE 15A – DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES

NC Department of Environment and Natural Resources T15A: 18A[removed]This contains amendments effective February 1, 2004 TITLE 15A – DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES

Add to Reading List

Source URL: ehs.ncpublichealth.com

Language: English - Date: 2012-02-21 11:03:01
43415A NCAC 18A[removed]MINIMUM STANDARDS FOR PRECAST REINFORCED CONCRETE TANKS (a) The following are minimum standards of design and construction of precast reinforced concrete septic tanks: (1) The minimum requirement for t

15A NCAC 18A[removed]MINIMUM STANDARDS FOR PRECAST REINFORCED CONCRETE TANKS (a) The following are minimum standards of design and construction of precast reinforced concrete septic tanks: (1) The minimum requirement for t

Add to Reading List

Source URL: reports.oah.state.nc.us

Language: English - Date: 2013-04-12 06:09:52
43515A NCAC 18A[removed]APPROVAL AND PERMITTING OF ON-SITE SUBSURFACE WASTEWATER SYSTEMS, TECHNOLOGIES, COMPONENTS, OR DEVICES (a) Experimental, controlled demonstration, and innovative wastewater systems (hereinafter referr

15A NCAC 18A[removed]APPROVAL AND PERMITTING OF ON-SITE SUBSURFACE WASTEWATER SYSTEMS, TECHNOLOGIES, COMPONENTS, OR DEVICES (a) Experimental, controlled demonstration, and innovative wastewater systems (hereinafter referr

Add to Reading List

Source URL: reports.oah.state.nc.us

Language: English - Date: 2013-04-12 06:27:40
    43615A NCAC 18A[removed]RESPONSIBILITIES (a) The permitting of a wastewater system shall be the responsibility of agents authorized by the State in accordance with G.S. 130A-40, 130A-50, and registered with the State of North

    15A NCAC 18A[removed]RESPONSIBILITIES (a) The permitting of a wastewater system shall be the responsibility of agents authorized by the State in accordance with G.S. 130A-40, 130A-50, and registered with the State of North

    Add to Reading List

    Source URL: reports.oah.state.nc.us

    Language: English - Date: 2013-04-12 05:49:57
    43715A NCAC 18A[removed]SEWAGE FLOW RATES FOR DESIGN UNITS (a) In determining the volume of sewage from dwelling units, the flow rate shall be 120 gallons per day per bedroom. The minimum volume of sewage from each dwelling u

    15A NCAC 18A[removed]SEWAGE FLOW RATES FOR DESIGN UNITS (a) In determining the volume of sewage from dwelling units, the flow rate shall be 120 gallons per day per bedroom. The minimum volume of sewage from each dwelling u

    Add to Reading List

    Source URL: reports.oah.state.nc.us

    Language: English - Date: 2013-04-12 06:03:40
    43815A NCAC 18A[removed]DEFINITIONS The following definitions shall apply throughout this Section: (1)

    15A NCAC 18A[removed]DEFINITIONS The following definitions shall apply throughout this Section: (1) "Alluvial Soils" means stratified soils without distinct horizons, deposited by flood waters. (2)

    Add to Reading List

    Source URL: reports.oah.state.nc.us

    Language: English - Date: 2013-04-12 05:45:45
    439Microsoft Word - 15a ncac 18a[removed]doc

    Microsoft Word - 15a ncac 18a[removed]doc

    Add to Reading List

    Source URL: ehs.ncpublichealth.com

    Language: English - Date: 2012-02-21 11:03:01
      44015A NCAC 18A[removed]CRITERIA FOR DESIGN OF ALTERNATIVE SEWAGE SYSTEMS (a) LOW-PRESSURE PIPE SYSTEMS: Low-pressure pipe (LPP) systems with a two to five-foot pressure head may be utilized on sites which are SUITABLE or PRO

      15A NCAC 18A[removed]CRITERIA FOR DESIGN OF ALTERNATIVE SEWAGE SYSTEMS (a) LOW-PRESSURE PIPE SYSTEMS: Low-pressure pipe (LPP) systems with a two to five-foot pressure head may be utilized on sites which are SUITABLE or PRO

      Add to Reading List

      Source URL: reports.oah.state.nc.us

      Language: English - Date: 2013-04-12 06:13:20